Core Breaking Unit for Metal Clad Switchgear
Tailored specifically for indoor medium-voltage metal-clad switchgear, this device is the primary switching and fault-clearing apparatus in medium-voltage substations and distribution rooms. In data centers, industrial manufacturing facilities, healthcare complexes, and rail transit traction networks, this Indoor Vacuum Circuit Breaker racks into standard KYN28 or KYN61 switchgear enclosures, handling daily operational switching as well as rapid short-circuit fault clearing.

Reliable Withdrawable Truck and Long Mechanical Life
Constructed on a precision withdrawable truck mechanism with integrated interlocks, the breaker moves smoothly between the Connected and Test positions without binding. The vacuum interrupter features high-purity ceramic chambers and low-surge copper-chromium alloy contacts, providing high arc-quenching capability with low contact erosion. With surface-hardened drive linkages, the mechanism delivers a mechanical endurance exceeding 10,000 cycles, making it suitable for frequent switching of capacitor banks and industrial motors.

Product Specifications
|
Parameter |
Value |
|
Series |
ZN Series (Mainly ZN85-40.5) |
|
Rated Voltage |
10kV, 24kV, 40.5kV |
|
Structure Type |
Withdrawable Truck Type |
|
Rated Current |
1250A - 2000A |
|
Short-circuit Breaking Current |
25kA / 31.5kA |
|
Mechanical Endurance |
>10000 Cycles |
Seamless Switchgear Integration and Customization
Our facility operates extensive CNC punching, bending, and laser-cutting centers, ensuring close dimensional control between the circuit breaker tulip contacts and switchgear spouts. We can tailor interlocking levers, secondary plug pin configurations, and auxiliary control voltages to match various cubicle designs.

Interlock Verification and Wooden Crate Dispatch
Before release, every Indoor Vacuum Circuit Breaker is mounted into test jigs to verify mechanical interlocking, loop contact resistance, and power frequency insulation. Units are then anchored within individual wooden crates with wheel chocks and protective film to prevent movement and humidity damage during ocean shipping.

FAQ
Q: Are type test reports available for integration into KYN28 switchgear?
A: Yes. We supply complete third-party type test reports and electrical qualification certificates required for technical approvals and customs clearance.
Q: What technical support is available during site installation?
A: We provide a 12-month factory warranty, 24-hour technical response, detailed mechanical diagrams, and remote video guidance for racking, commissioning, and maintenance.
Hot Tags: indoor vacuum circuit breaker, China indoor vacuum circuit breaker manufacturers, suppliers, factory, breaker auxiliary contacts, breaker protection relay, HVDC high voltage circuit breaker, Protective outdoor SF6 circuit breaker, Reliable high voltage air circuit breaker, Substation outdoor vacuum circuit breaker