Cost Effective Air Insulated RMU for Urban Grids
In secondary distribution networks operating at 10kV to 40.5kV, deploying SF6 gas-filled equipment is not always economical or environmentally practical. This Air Insulated Ring Main Unit utilizes ambient air as its primary insulating medium, combined with solid-insulation barriers and electric field modeling to achieve compact dimensions without pressurized gas vessels. It provides a practical solution for municipal substations, commercial buildings, and infrastructure projects.

SF6 Free Design and Zero Gas Maintenance
Because the main busbars and switching components operate in ambient air, this equipment eliminates sulfur hexafluoride greenhouse gas usage. Station personnel avoid tracking gas pressure gauges, managing leak-detection protocols, or handling gas recycling at end-of-life, and the switchgear remains free from low-temperature gas liquefaction concerns. The panel incorporates vacuum or air-break load switches to ensure reliable feeder switching and protection.
Product Specifications
|
Parameter |
Value |
|
Series |
HXGN Ring Main Unit Series |
|
Rated Voltage |
10kV, 40.5kV |
|
Insulation Medium |
Air Insulation |
|
Available Ways |
2 - 6 Ways |
|
Main Internal Device |
Load Break Switch |
|
Core Advantages |
Simple Maintenance, Lower Capital Cost |
Modular Bay Extension and Multi Way Configurations
The cubicles use a modular design that can be joined to form multi-panel lineups, including incoming switch bays, outgoing transformer protection bays, metering cubicles, and bus-sectionalizing units. Adjacent panels interconnect via through-wall insulated busbar bushings. Future capacity upgrades require only unbolting busbar links and coupling an additional bay, simplifying substation expansions.
Dielectric Withstand Testing and Palletized Crating
Each Air Insulated Ring Main Unit undergoes full mechanical interlock validation, primary power-frequency insulation testing, and auxiliary loop resistance measurements. For export delivery, panels are braced and packaged on reinforced solid-wood pallets inside heavy weather-resistant crates, complying with standard FOB maritime logistics requirements.
FAQ
Q: What are the operational advantages of air-insulated RMUs over gas-insulated switchgear?
A: Air-insulated units offer clear internal visibility without sealed gas compartments. Switch blades and earth contacts can be inspected directly, component replacements do not require specialized gas-handling gear, and capital expenditure and lifecycle maintenance costs are substantially lower.
Q: What is the turnaround time from single-line diagram (SLD) approval to dispatch?
A: Engineering review and layout drawings are completed within 24 hours of SLD submission. Standard 2-way to 4-way panel configurations typically complete fabrication, assembly, and testing within 15 to 20 days.
Hot Tags: air insulated ring main unit, China air insulated ring main unit manufacturers, suppliers, factory, distribution switchgear panel, fixed switchgear, low voltage switchgear, medium voltage electrical switchgear, Reliable box type substation, switchgear frequency rating