Cost Effective Load Breaking for MV Lines
For distribution feeders where full-scale circuit breakers are cost-prohibitive but reliable load breaking is essential, this switch offers an economical switching solution. Serving industrial incoming lines, solar step-up transformer enclosures, and overhead line sectionalizing points, this High Voltage Interrupter Switch handles normal load currents and magnetizing currents under rated system voltages.

Robust Spring Mechanism and Fast Break Circuit
The drive system utilizes heat-treated alloy steel energy-storage springs that release stored mechanical energy over-center, snapping the contacts open at high velocity. Primary copper current paths are heavy-gauge silver-plated extrusions that maintain low contact resistance. Sacrificial arcing tips engage prior to and separate after the main current-carrying blades, shielding the primary contact surfaces from thermal arc degradation.

Product Specifications
|
Parameter |
Value |
|
Series |
FLN / FZW Series |
|
Rated Voltage |
10kV, 24kV, 40.5kV |
|
Core Function |
Load Current Interruption (Non-Fault Breaking) |
|
Operating Mechanism |
Stored Energy Spring Mechanism |
|
Warranty Period |
12 Months (From Dispatch Date) |
Switchgear Compatibility and Drawing Alignment
Manufactured in our standardized sheet metal facility utilizing high-precision CNC punch presses, the mounting channels, insulator phase spacings, and drive shaft geometries can be adapted to specific customer switchgear drawings. This ensures smooth installation without binding or busbar misalignment.

Loop Resistance Testing and Dielectric Check
Before packaging, every High Voltage Interrupter Switch undergoes micro-ohm contact resistance screening, three-phase contact synchronization verification, and power-frequency overvoltage testing. Moving assemblies are braced, greased, and strapped within solid-wood crates to eliminate transit vibration.

FAQ
Q: Can this interrupter switch clear short-circuit faults independently?
A: No. It is rated exclusively for load and no-load switching. For short-circuit protection, it must be paired with series-connected current-limiting fuses fitted with striker-pin trip linkages.
Q: Are volume pricing discounts available?
A: Yes. Tiered commercial pricing applies to volume orders and long-term supply agreements.
Hot Tags: high voltage interrupter switch, China high voltage interrupter switch manufacturers, suppliers, factory, Ac Load Switch, IEC compliant high current load switch, load break switch isolator, load switch rated voltage, Power Load Switch, two position load switch