Smart Switching Node for Distribution RMU
Engineered for 10kV to 40.5kV urban secondary distribution networks, compact ring main units (RMU), and containerized transformer substations, this equipment handles sectionalizing and load-transfer switching. This Vacuum Load Switch is fully rated to make and break nominal load currents while retaining short-circuit making capacity. Coordinated with automated distribution feeder terminals (FTU/DTU), it facilitates automated feeder reconfiguration and fault isolation.

Vacuum Interrupter and Self Aligning Contacts
Primary current interruption takes place within hermetically sealed ceramic vacuum interrupters, eliminating toxic emissions and external arcing. Contacts feature specialized copper-chromium contact faces that resist electrical erosion and contact welding. The unit is driven by a dual-spring fast-acting mechanism whose operating speed is entirely independent of the operator, preventing slow-opening arc damage.

Product Specifications
|
Parameter |
Value |
|
Series |
FLN36 Series |
|
Rated Voltage |
10kV, 24kV, 40.5kV |
|
Rated Current |
630A / 1250A |
|
Rated Breaking Current |
630A |
|
Short-time Withstand Current |
20kA / 2s |
|
Arc Quenching Medium |
SF6 / Vacuum (Optional) |
Integrated Earth Switch and Interlocking
The chassis incorporates an integral fast-acting earthing switch with identical dynamic short-circuit making capacity. Robust mechanical interlocks coordinate the Closed, Open, and Earthed positions, preventing accidental grounding of live circuits or closing the load switch onto an active earth. Every Vacuum Load Switch completes dozens of mechanical interlocking validation cycles on automated test rigs prior to crating.

Dustproof Wrapping and Wooden Crate Transport
The complete switch assembly is sealed inside heavy antistatic vapor-barrier bags with desiccant and secured inside high-strength plywood crates fitted with perimeter skids to simplify handling by forklift and crane.

FAQ
Q: Does the switch provide auxiliary contacts for remote SCADA integration?
A: Yes. It includes a multi-pole auxiliary switch assembly with gold-plated contact points, providing reliable Closed, Open, and Earthed status indications to remote telemetry systems.
Q: How are shipping damages handled under FOB terms?
A: Risk transfers to the buyer once the cargo passes the ship's rail at the loading port, and transit claims should be lodged with the carrier or cargo insurer. Our factory provides full replacement parts and repair assistance for any issues originating from factory packaging or manufacturing faults.
Hot Tags: vacuum load switch, China vacuum load switch manufacturers, suppliers, factory, IEC standard power load break switch, load break switch, load break switch dielectric withstand, Reliable DC load break switch, Reliable high current load switch, Reliable high voltage load switch